Rev Up & Re Exciting Your Generator: Tips For Peak Power
Re exciting a generator is the critical process of restoring its magnetic field, essentially priming the unit to produce electricity when needed. Without this essential step, even a mechanically sound generator will fail to initiate power output during an outage. This procedure applies to both standby emergency systems and portable units, ensuring the excitation winding is energized to create the necessary magnetic flux. Understanding how to properly re excite your generator can mean the difference between immediate power restoration and frustrating downtime.
Understanding Generator Excitation and Why It Fails
Generator excitation is the process of creating a magnetic field within the generator's alternator. This magnetic field is essential for converting mechanical energy from the engine into electrical energy. Typically, the excitation system uses a portion of the generator's own output to power its electromagnets, creating a self-sustaining loop. However, this residual magnetism can dissipate due to prolonged disuse, low battery power for the control board, or a fault in the automatic voltage regulator (AVR).
Common Causes of Lost Magnetism
- Prolonged periods of inactivity where the generator is not run.
- Battery failure in generators that rely on battery-powered excitation systems.
- Disconnection or failure of the automatic voltage regulator (AVR).
- Surges or electrical faults that discharge the residual magnetism.
The Manual Re Excitation Procedure
If your generator fails to start producing voltage, a manual re excitation or "flash" is often the solution. This involves briefly applying a direct current (DC) voltage to the generator's field winding to restore the magnetic field. The standard method requires a 12-volt DC power source, such as a car battery.
Step-by-Step Instructions
- Ensure the generator is turned off and spark plug disconnected for safety.
- Locate the generator's field winding terminals, usually labeled "F+" and "F-" or "Field."
- Touch the positive terminal of a 12V battery to the "F+" terminal and the negative terminal to the "F-" terminal for approximately 5 seconds.
- Remove the battery connections and attempt to start the generator normally.
Using a Smart Starting Procedure
For modern generators, the process is often simplified through the design of the control panel. Many units feature a dedicated "Excitation" or "Restoration" button that automates the flashing process internally. When pressed, the system momentarily creates a spark or DC pulse to reignite the magnetic field without requiring external tools.
When to Use This Feature
Utilize this function immediately after a power outage when you notice the control panel lights are on but the voltage meter reads zero. It is a standard troubleshooting step that should be performed before calling a technician, saving time and service costs. Always refer to your operator's manual for the specific location and function of this button, as placement varies by manufacturer.
Troubleshooting After Re Excitation
Successfully re exciting the generator should result in the voltage building up to the desired level within a few seconds of starting the engine. If the voltage remains low or fluctuates wildly after the procedure, the issue may extend beyond simple magnetism loss. Problems with the AVR, capacitors, or the winding coils themselves might be the culprit.
Next Steps If It Doesn't Work
- Check the engine speed; it must be at the recommended RPM for voltage regulation.
- Inspect the battery voltage of the unit; a weak battery cannot power the AVR.
- Look for any error codes displayed on the digital control panel.
- Consult a licensed electrician if the problem persists to diagnose the rectifier or windings.