Winterize Your RV Girard Tankless Water Heater: Essential Steps & Tips
As the temperature drops and the first frost of the season appears, the comfort and convenience of your RV depend on a reliable heating system, specifically the water heater. For owners of a Girard tankless model, understanding how to winterize rv girard tankless water heater is not just a recommendation; it is an absolute necessity to prevent costly internal damage. Unlike traditional tank models, the compact heat exchanger and flow sensors of a tankless system are particularly vulnerable to freezing, which can lead to ruptured components or electronic failure.
Why Winterization is Non-Negotiable for Tankless Models
The primary reason you must prioritize this task is the risk of standing water freezing inside the unit. Even a small amount of residual water within the heat exchanger or the plumbing lines can expand as it turns to ice, creating enough pressure to crack delicate components. Because a tankless water heater integrates directly into the water lines, a failure here can compromise the entire freshwater system. Taking the time to perform a thorough winterization protects your investment and ensures your next camping trip does not begin with a plumbing disaster.
Preparing the Unit for the Shutdown
Before you introduce any winterizing agents into the system, you must prepare the heater physically. Start by turning off the main power supply to the unit at the circuit breaker or the RV's main power panel. Next, locate the water heater's dedicated water intake valve and turn it off; this is usually found on the freshwater inlet line. Finally, you need to open the hot water faucet inside your RV—both in the kitchen and bathroom—to relieve pressure and drain the lines leading to and from the heater.
The Step-by-Step Winterization Process
With the unit powered down and the water supply secured, you can proceed with the actual winterization. The goal is to force RV antifreeze through the system to displace any remaining freshwater. It is critical to select a product specifically labeled as "potable water safe" and non-toxic, typically containing propylene glycol. Avoid ethylene glycol, which is toxic and strictly for automotive use. You will generally connect a short hose to the city water inlet and route it to a container holding the antifreeze solution.
Operational Steps and Best Practices
To execute the winterization correctly, follow these steps methodically:
- Open the hot water valve inside the RV to the "on" position.
- Turn on the RV water pump to circulate the antifreeze.
- Slowly pour the pre-mixed RV antifreeze into the gravity feed or pressurized supply line.
- Allow the system to run until you smell antifreeze at the hot water faucet, ensuring the lines are fully treated.
- Once complete, turn off the water pump and pour a small amount of antifreeze into the shower drains and toilet.
Specific Considerations for the Girard Tankless Unit
When handling a Girard tankless water heater, there is an additional critical step regarding the gas supply. These units run on propane to generate heat, and leaving a gas connection active during the winter poses a safety risk and can lead to moisture condensation inside the burner assembly. You must locate the gas cylinder valve and turn it to the "off" position. Furthermore, if your Girard unit has a battery-powered fan or ignition system, you should also disconnect the 12-vDC power to prevent parasitic drain or accidental activation in extremely cold conditions.
Protecting the Plumbing Infrastructure
Winterizing the water heater is only one part of the equation; you must also address the pipes and drains. After treating the heater, ensure that all low points in the freshwater and hot water lines are drained. Gravity is your best tool here—simply open all faucets (hot and cold) and allow the lines to drain completely. For holding tanks and gray water pipes, you can introduce antifreeze using the same gravity method to ensure that residual water does not linger and freeze, which could burst the tanks or seals.
Reactivating the System in Spring
When the weather warms and you are ready to reactivate your RV, reversing the winterization process is essential. First, ensure the water heater is switched back to the "on" gas setting and check that the battery disconnect is reconnected if you removed it. Turn the water supply back on and check the water heater pressure relief valve to ensure it is functioning correctly. As you begin to run water, inspect the unit for any signs of leaks or unusual noises, which could indicate that components suffered stress during the freezing period. Following a thorough check confirms that your Girard tankless system is ready to provide efficient hot water without issue.